Drac: Difference between revisions
From Halfface
Jump to navigationJump to search
No edit summary |
|||
| Line 4: | Line 4: | ||
racadm racreset soft | racadm racreset soft | ||
=racadm(Manage dell sever via ssh idrac)= | =racadm(Manage dell sever via ssh idrac)= | ||
List system events. | ==List system events.== | ||
racadm getsel | racadm getsel | ||
How many event in log | ==How many event in log== | ||
racadm getsel -i | racadm getsel -i | ||
Read 7 event from line 10. | ==Read 7 event from line 10.== | ||
racadm getsel -s 10 -c 7 | racadm getsel -s 10 -c 7 | ||
Read lifecycle log | ==Read lifecycle log== | ||
racadm lclog view | racadm lclog view | ||
Read lifecycle logs of warning critical version. | ==Read lifecycle logs of warning critical version.== | ||
racadm lclog view -s Warning,Critical -n 5 | racadm lclog view -s Warning,Critical -n 5 | ||
Reset idrac | ==Reset idrac== | ||
racadm racreset -f | racadm racreset -f | ||
Version of idrac | ==Version of idrac== | ||
racadm getversion | racadm getversion | ||
Is sol enabled | ==Is sol enabled== | ||
racadm get iDRAC.IPMISOL | racadm get iDRAC.IPMISOL | ||
Login via sol/serial | ==Login via sol/serial== | ||
racadm console com2 | racadm console com2 | ||
Short info about system | ==Short info about system== | ||
racadm getsysinfo | racadm getsysinfo | ||
Long output inventory | ==Long output inventory== | ||
hwinventory | hwinventory | ||
View settings | ==View settings== | ||
racadm get BIOS.ProcSettings.ProcVirtualization | racadm get BIOS.ProcSettings.ProcVirtualization | ||
Set value | ==Set value== | ||
racadm set BIOS.ProcSettings.ProcVirtualization Disabled | racadm set BIOS.ProcSettings.ProcVirtualization Disabled | ||
[Key=BIOS.Setup.1-1#ProcSettings] | [Key=BIOS.Setup.1-1#ProcSettings] | ||
| Line 37: | Line 37: | ||
command. For more information about the "jobqueue" command, see RACADM | command. For more information about the "jobqueue" command, see RACADM | ||
help. | help. | ||
==Cold restart (hard reset)== | |||
racadm serveraction hardreset | |||
==Full power cycle (off → on)== | |||
racadm serveraction powercycle | |||
==Force shutdown and power-up manually== | |||
racadm serveraction powerdown | |||
racadm serveraction powerup | |||
Revision as of 07:44, 22 October 2025
get system information
racadm getsysinfo
reset drac
racadm racreset soft
racadm(Manage dell sever via ssh idrac)
List system events.
racadm getsel
How many event in log
racadm getsel -i
Read 7 event from line 10.
racadm getsel -s 10 -c 7
Read lifecycle log
racadm lclog view
Read lifecycle logs of warning critical version.
racadm lclog view -s Warning,Critical -n 5
Reset idrac
racadm racreset -f
Version of idrac
racadm getversion
Is sol enabled
racadm get iDRAC.IPMISOL
Login via sol/serial
racadm console com2
Short info about system
racadm getsysinfo
Long output inventory
hwinventory
View settings
racadm get BIOS.ProcSettings.ProcVirtualization
Set value
racadm set BIOS.ProcSettings.ProcVirtualization Disabled
[Key=BIOS.Setup.1-1#ProcSettings]
RAC1017: Successfully modified the object value and the change is in
pending state.
To apply modified value, create a configuration job and reboot
the system. To create the commit and reboot jobs, use "jobqueue"
command. For more information about the "jobqueue" command, see RACADM
help.
Cold restart (hard reset)
racadm serveraction hardreset
Full power cycle (off → on)
racadm serveraction powercycle
Force shutdown and power-up manually
racadm serveraction powerdown racadm serveraction powerup