Line 44: Line 44:
  racadm serveraction powerdown
  racadm serveraction powerdown
  racadm serveraction powerup
  racadm serveraction powerup
==look at state of disks==
racadm storage get pdisks -o -p State,Name,Size,MediaType

Latest revision as of 09:18, 22 October 2025

get system information

racadm getsysinfo

reset drac

racadm racreset soft

racadm(Manage dell sever via ssh idrac)

List system events.

racadm getsel

How many event in log

racadm getsel -i

Read 7 event from line 10.

racadm getsel -s 10 -c 7

Read lifecycle log

racadm lclog view

Read lifecycle logs of warning critical version.

racadm lclog view -s Warning,Critical -n 5

Reset idrac

racadm racreset -f

Version of idrac

racadm getversion

Is sol enabled

racadm get iDRAC.IPMISOL

Login via sol/serial

racadm console com2

Short info about system

racadm getsysinfo

Long output inventory

hwinventory

View settings

racadm get BIOS.ProcSettings.ProcVirtualization

Set value

racadm set BIOS.ProcSettings.ProcVirtualization Disabled
[Key=BIOS.Setup.1-1#ProcSettings]
RAC1017: Successfully modified the object value and the change is in
       pending state.
       To apply modified value, create a configuration job and reboot
       the system. To create the commit and reboot jobs, use "jobqueue"
       command. For more information about the "jobqueue" command, see RACADM
       help.

Cold restart (hard reset)

racadm serveraction hardreset

Full power cycle (off → on)

racadm serveraction powercycle

Force shutdown and power-up manually

racadm serveraction powerdown
racadm serveraction powerup

look at state of disks