Drac: Difference between revisions
From Halfface
Jump to navigationJump to search
| Line 44: | Line 44: | ||
racadm serveraction powerdown | racadm serveraction powerdown | ||
racadm serveraction powerup | racadm serveraction powerup | ||
==look at state of disks== | |||
racadm storage get pdisks -o -p State,Name,Size,MediaType | |||
Latest revision as of 09:18, 22 October 2025
get system information
racadm getsysinfo
reset drac
racadm racreset soft
racadm(Manage dell sever via ssh idrac)
List system events.
racadm getsel
How many event in log
racadm getsel -i
Read 7 event from line 10.
racadm getsel -s 10 -c 7
Read lifecycle log
racadm lclog view
Read lifecycle logs of warning critical version.
racadm lclog view -s Warning,Critical -n 5
Reset idrac
racadm racreset -f
Version of idrac
racadm getversion
Is sol enabled
racadm get iDRAC.IPMISOL
Login via sol/serial
racadm console com2
Short info about system
racadm getsysinfo
Long output inventory
hwinventory
View settings
racadm get BIOS.ProcSettings.ProcVirtualization
Set value
racadm set BIOS.ProcSettings.ProcVirtualization Disabled
[Key=BIOS.Setup.1-1#ProcSettings]
RAC1017: Successfully modified the object value and the change is in
pending state.
To apply modified value, create a configuration job and reboot
the system. To create the commit and reboot jobs, use "jobqueue"
command. For more information about the "jobqueue" command, see RACADM
help.
Cold restart (hard reset)
racadm serveraction hardreset
Full power cycle (off → on)
racadm serveraction powercycle
Force shutdown and power-up manually
racadm serveraction powerdown racadm serveraction powerup
look at state of disks
racadm storage get pdisks -o -p State,Name,Size,MediaType